Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 250
Filter
1.
J. oral res. (Impresa) ; 12(1): 204-216, abr. 4, 2023. tab, ilus
Article in English | LILACS | ID: biblio-1518183

ABSTRACT

Aim: To evaluate the bond strength of a universal adhesive system to dentin submitted to radiotherapy. Materials and Methods: Sixty extracted human teeth were divided into two groups (n = 30): without radiotherapy (control); with radiotherapy, according to the adhesive protocol (n=15): ER-etch-and-rinse (acid + Single Bond Uni-versal); SE-self-etch (Single Bond Universal). The analyzes were shear bond strength (SBS) (n=10), failure pattern (n=10) and scanning electron microscopy (n=5). Data was analyzed by a two-way ANOVA (α =0.05). Results: The radiotherapy decreased SBS of the restorative material to dentin (p<0.0001). The ER protocol provided lower bond strength values (p<0.001). The predominant type of fracture without radiotherapy was mixed (SE), cohesive to the material (ER). Both protocols presented adhesive failures with radiotherapy. Teeth had a hybrid layer and long resin tags (without radiotherapy) and few tags (with radiotherapy). Conclusions: The SE adhesive mode favors the shear bond strength of resin to dentin in teeth submitted to radiotherapy.


Objetivo: Evaluar la fuerza de adhesión de un sistema adhesivo universal a la dentina sometida a radioterapia. Materiales y Métodos: Sesenta dientes humanos extraídos se dividieron en dos grupos (n = 30): sin radioterapia (control); con radioterapia, según protocolo adhesivo (n=15): ER-grabado y enjuague (ácido + Single Bond Universal); autograbado SE (Single Bond Universal). Los análisis ejecutados fueron resistencia al cizallamiento (SBS) (n=10), patrón de falla (n=10) y microscopía electrónica de barrido (n=5). Los datos se sometieron al test de ANOVA de dos vías (α =0,05). Resultados: La radioterapia disminuyó la SBS del material restaurador a la dentina (p<0,0001). El protocolo ER proporcionó valores de fuerza de unión más bajos (p<0,001). El tipo de fractura predominante sin radioterapia fue mixta (SE), cohesiva al material (ER). Ambos protocolos presentaron fallas adhesivas con radioterapia. Los dientes tenían una capa híbrida y colas de resina largas (sin radioterapia) o pocas colas de resina (con radioterapia). Conclusión: El modo adhesivo SE favorece la resistencia al corte de la resina a la dentina en dientes sometidos a radioterapia.


Subject(s)
Humans , Dental Bonding/methods , Dentin-Bonding Agents/chemistry , Dental Cements/chemistry , Dental Stress Analysis/methods , Composite Resins , Dentin
2.
J. oral res. (Impresa) ; 11(5): 1-13, nov. 23, 2022. ilus, tab
Article in English | LILACS | ID: biblio-1436941

ABSTRACT

Objetive: To compare the clinical behavior of two types of Bulk Fill composite resins and a nanohybrid resin at 18 months in occlusal restorations. Material and Methods: Three occlusal restorations were performed in each one of the 55 participants. They were randomly distributed into three groups, TN: Tetric-N-Ceram Bulk-Fill, FK: Filtek Bulk-Fill, and Z350: Filtek Z350XT. Adhesive techniques and restorative procedures were performed according to the manufacturer's instructions for each restorative material used. In TN and FK an increment of 4mm was applied, and in Z350 increments of ≤2mm depth were applied. Two calibrated operators evaluated the restorations at baseline and at 18 months using the FDI World Dental Federations system (1: excellent, 2: good, 3: satisfactory, 4: unsatisfactory, 5: poor) for clinical marginal staining (MS) properties, fracture-retention (FR), superficial texture (ST), marginal integrity (MI), postoperative sensitivity (PS) and caries (C). Kruskal-Wallis and Wilcoxon were used to compare the 3 groups at 18 months (5% significance). Results: 38 patients with a total of 114 restorations were assessed, being evaluated with excellent clinical behavior; MI, 78.9% in Z350, 89.51% in TN and 81.6% in FK; ST 73.5% in Z350, 86.8% in TN, and 84.2% in FK; MS 84.2% in Z350, 84.2% in TN, and 91.2% in FK; PS 100% in Z350 and 97.3% in TN and FK; in C and FR, 100% in the 3 groups. There were no significant differences between the three groups (p>0.05). Conclusion: The three resins studied presented a good clinical performance at 18 months without showing significant differences in the clinical properties evaluated.


Objetivo: Comparar el comportamiento clínico a 18 meses en restauraciones oclusales entre dos tipos de resinas compuestas Bulk Fill y una resina nanohíbrida. Material y Métodos: En 55 participantes se realizaron 3 restauraciones oclusales en cada paciente, distribuidas aleatoriamente en 3 grupos, TN: Tetric-N-Ceram Bulk-Fill, FK: Filtek Bulk-Fill y Z350: Filtek Z350XT. Las técnicas adhesivas y procedimientos restauradores fueron realizados según las instrucciones de los fabricantes de cada material restaurador utilizado. En TN y FK se aplicó un incremento de 4mm y en Z350 se aplicó incrementos ≤ 2 mm de profundidad. Dos operadores calibrados evaluaron las restauraciones al baseline y a los 18 meses mediante el sistema FDI World Dental Federations (1: excelente, 2: aceptable, 3: suficiente, 4: insatisfactorio, 5: inaceptable) en las propiedades clínicas de tinción marginal (TM), fractura-retención (FR), textura superficial (TS), integridad marginal (IM), sensibilidad postoperatoria (SP) y caries (C). Se utilizó Kruskal-Wallis y Wilcoxon para la comparación de los 3 grupos a 18 meses (significancia de 5%). Resultados: Se controlaron 38 pacientes con un total de 114 restauraciones, siendo evaluados con comportamiento clínico excelente; IM, 78.9% en Z350, 89.51% en TN y 81.6% en FK; TS 73.5%, en Z350, 86.8% en TN y 84.2% en FK; TM, 84.2% en Z350, 84.2% en TN y 91.2% en FK; SP 100% en Z350 y 97,3% en TN y FK; en C y FR 100% en los 3 grupos. No hubo diferencias significativas entre los 3 grupos (p>0,05). Conclusión: Las 3 resinas estudiadas presentaron un buen desempeño clínico a 18 meses sin mostrar diferencias significativas en las propiedades clínicas evaluadas.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Young Adult , Composite Resins/chemistry , Dental Cements/chemistry , Dental Restoration, Permanent/methods , Chile/epidemiology , Resin Cements/chemistry , Dental Restoration Wear
3.
Rev. Ciênc. Plur ; 7(2): 61-73, maio 2021. tab
Article in Portuguese | BBO, LILACS | ID: biblio-1282737

ABSTRACT

Introdução:Os sistemas adesivos possibilitama execução de restaurações estéticas e minimamente invasivas, sendo, portanto,objeto de pesquisas para contornar os problemas que se apresentam no procedimento restaurador.Objetivo:Avaliar in vitroa resistência de união de um sistema adesivo autocondicionante, e deste modificado com soluções extrativas de semente de uva.Metodologia:Duas soluções extrativas foram preparadas comextrato de semente de uva em pó dissolvido em acetona e etanol. A partir delas e de umadesivo,seis sistemas adesivos autocondicionantes experimentais foram preparados, diferindo quanto aosolvente utilizado eàsproporções entre adesivo puro e solução extrativa(7,5%, 15% e 30%). Setenta incisivos bovinos hígidos tiveram as raízes removidas com disco de carborundum e as faces vestibulares desgastadas comlixas d'água de granulação 120, 240, 600 e 1200 sob refrigeração até expor a dentina superficial. Os dentes foram distribuídos aleatoriamenteem sete grupos distintos: Controle; A7,5; A15; A30; E7,5; E15; e E30, contendo 10 elementos cada. A aplicação dos adesivos foi executada de acordo com as recomendações do fabricante do adesivo controle. A restauração foi realizada com uma matriz de silicone com dimensões 2mm de altura e 4mm de diâmetro e inserido o material restaurador em incremento único e fotopolimerizado por 40s. Após três meses armazenados em água destilada, os espécimes foram submetidos ao teste de resistência de união. Foi empregado ométodo estatísticoTeste Paramétrico Anova 1 Fator e pós-teste de Tamhane (p<0,05). Resultados:Os grupos A7,5, E7,5 e E30 não apresentaram diferença em relação ao grupo Controle; A15 e A30 mostraram desempenho estatisticamente semelhante entre si; e E15 não apresentou diferença estatística em relação aos outros adesivos.Conclusões:A adição de proantocianidina teve efeitos diferentes,dependendodos solventes e das concentrações utilizadas, mas sem alterar significativamente o desempenho do adesivo (AU).


Introduction:Adhesive systems make it possible to perform aestheticand minimally invasive restorations, being the subject of research to circumvent the problems that arise in the restorative procedure.Objective:Evaluate in vitrothe bond strength of a self-etching adhesive system,and modified with extractive grape seed solutions. Methodology:Two extractive solutions were prepared with powdered grape seed extract dissolved in acetone and ethanol. From them and an adhesive, six experimental self-etching adhesive systems were prepared, differing in terms of the solvent used and the proportions between pure adhesive and extractive solution(7.5%, 15% and 30%). Seventy healthy bovine incisors had their roots removed with carborundum disc and the vestibular faces were worn with sandpaper with granulation water 120, 240, 600 and 1200 under refrigeration until the superficial dentin was exposed. The teeth were randomly assigned to seven different groups: Control; A7.5; A15; A30; E7.5; E15; and E30, containing 10 elements each. The application of the adhesives was carried out according to the recommendations of the manufacturer of the control adhesive. The restoration was performed with a silicone matrix with dimensions 2mm high and 4mm indiameter and the restorative material was inserted in a single increment and light cured for 40s. After three months stored in distilled water, the specimens were submitted to the bond strength test. The statistical method Parametric Test Anova 1 Factor and Tamhane post-test (p<0.05) were used. Results:Groups A7.5, E7.5 and E30 showed no difference in relation to the Control group; A15 and A30 showed a statistically similar performance; and E15 showed no statistical difference in relation to the other adhesives. Conclusions:The addition of proanthocyanidin had different effects, depending on the solvents and concentrations used, but without significantly altering the performance ofthe adhesive (AU).


Introducción: Sistemas adhesivos permiten realizar restauraciones estéticas y mínimamente invasivas, siendo objeto de investigación para sortear problemas que surgen en elprocedimiento restaurador. Objetivo: Evaluar in vitrola fuerza de unión de un sistema adhesivoautograbante y modificado con soluciones extractivas de semilla de uva. Metodología: Se prepararon dos soluciones extractivas con extracto de semilla de uva en polvo disuelto en acetona y etanol. A partir de ellos y de un adhesivo, se prepararon seis sistemas experimentales de adhesivos autograbantes, que se diferencian en cuanto al solvente utilizado y las proporciones entre adhesivo puro y solución extractiva (7,5%, 15% y 30%). Setenta incisivos bovinos sanos fueron removidos con un disco de carborundo y las caras vestibulares fueron usadas com lija de agua de granulación 120, 240, 600 y 1200 bajo refrigeración hasta que la dentina superficial quedo expuesta. Los dientes se asignaron aleatoriamente a siete grupos diferentes: Control; A7,5; A15; A30; E7,5; E15; y E30, que contiene 10 elementos cada uno. La aplicación de los adhesivos se realizó siguiendo las recomendaciones del fabricante del adhesivo de control. La restauración se realizó con matriz de silicona con 2mm de altura y 4mm de diámetro y el material restaurador se insertó en un solo incremento y se fotopolimerizó durante 40s. Tres meses después, almacenados em agua destilada, las muestras se sometieron a la prueba de resistencia de la unión. Se utilizó el método estadístico Prueba Paramétrica Factor Anova 1 y post-prueba de Tamhane (p<0,05). Resultados: Los grupos A7,5, E7,5 y E30 no mostraron diferencias em relación con el grupo Control; A15 y A30 mostraron un desempeño estadísticamente similar; y E15 no mostró diferencia estadística en relación con los otros adhesivos. Conclusiones: La adición de proantocianidina tuvo diferentes efectos, dependiendo de los disolventes y concentraciones utilizadas, pero sin alterar significativamente el rendimiento del adhesivo (AU).


Subject(s)
Animals , Cattle , Dental Polishing/instrumentation , Proanthocyanidins , Flexural Strength , Solvents , In Vitro Techniques/methods , Brazil , Analysis of Variance , Dental Cements/chemistry , Grape Seed Extract
4.
Acta odontol. latinoam ; 33(2): 82-89, Sept. 2020. graf
Article in English | LILACS | ID: biblio-1130737

ABSTRACT

ABSTRACT The aim of this study was to evaluate the degree of conversion, cytotoxicity, solubility and pH of photopolymerizable calciumbased cements submitted to preheating. The degree of conversion was analyzed by Fourier transform infrared, cytotoxicity by the MTT test and solubility through loss of mass. The data were subjected to statistical tests (ANOVA / Tukey's, p<0.05). The photopolymerizable materials showed a low degree of conversion, regardless of preheating. All materials caused a reduction in cell viability at 24 hours and 7 days, with the Dycal (control) being more cytotoxic. Heat had a positive effect on Biocal at 7 days. Dycal is the most soluble material. Heat had no effect on the solubility or pH of the polymerizable materials. It is concluded that photopolymerizable calcium-based cements have a low degree of conversion and are soluble, which results in mild to moderate cytotoxicity.


RESUMO O objetivo do presente estudo foi avaliar o grau de conversão, citotoxicidade, solubilidade e pH de cimentos à base de cálcio fotopolimerizáveis submetidos a pré-aquecimento. O grau de conversão foi analisado por espectroscopia no infravermelho com transformada de Fourier, a citotoxicidade pelo teste de MTT e a solubilidade através da perda de massa. Os dados foram submetidos a testes estatísticos (ANOVA/Tukey, p<0,05). Os materiais fotopolimerizáveis apresentaram baixo grau de conversão, independente do pré-aquecimento. Todos os materiais causaram redução da viabilidade celular nas análises de 24 horas e 7 dias, sendo que o Dycal (controle) apresentouse mais citotóxico e o calor apresentou efeito positivo sobre o Biocal na análise de 7 dias. O Dycal é o material mais solúvel e o calor não causou efeito na solubilidade e pH dos materiais polimerizáveis. Assim, conclui-se que os cimentos à base de cálcio fotopolimerizáveis apresentam baixo grau de conversão e são solúveis, que resulta em citotoxicidade suave e moderada.


Subject(s)
Humans , Calcium Hydroxide/toxicity , Cell Survival/drug effects , Dental Cements/chemistry , Pulp Capping and Pulpectomy Agents/toxicity , Calcium Hydroxide/chemistry , Calcium , Dental Cements/toxicity , Dental Pulp Capping , Light-Curing of Dental Adhesives , Photochemical Processes , Pulp Capping and Pulpectomy Agents/chemistry , Polymerization , Hydrogen-Ion Concentration
5.
Acta odontol. latinoam ; 33(2): 135-142, Sept. 2020. graf
Article in English | LILACS | ID: biblio-1130744

ABSTRACT

ABSTRACT This study evaluated the influence of the mode and time of solvent evaporation on the tensile strength (TS), flexural strength (FS) and elastic modulus (EM) of two adhesive systems: Scotchbond Multipurpose (SBMP) and Clearfil SE (CSEB). For this purpose, rectangular samples (2x1x7 mm) were prepared with 10 μL of primer and the solvents were evaporated with air spray at (23±1) ºC, (40±1) ºC and negative control (without spray). For each temperature, the times of 5, 20, 30, and 60 seconds were investigated. The statistical results showed that evaporation at 40±1ºC resulted in better EM for the two adhesives tested and all the evaporation times evaluated. However, there were no significant differences between the times and modes of evaporation for TS. The results of this study indicate that evaporation at a temperature of (40±1) °C could improve the elastic modulus of both adhesives tested, regardless of the evaporating time.


RESUMO Este estudo avaliou a influência do modo e do tempo de evaporação do solvente na resistência à tração (RT), resistência à flexão (RF) e módulo de elasticidade (MR) de dois sistemas adesivos: Scotchbond Multipurpose (SBMP) e Clearfil SE (CSEB). Para isso, amostras retangulares (2x1x7 mm) foram preparadas com 10 μL de primer e os solventes foram evaporados com aerossol a (23±1) ºC, (40±1) ºC e controle negativo (sem aerossol). Para cada temperatura, foram avaliados os tempos de 5, 20, 30 e 60 segundos. Os resultados estatísticos mostraram que a evaporação a (40±1) ºC resultou em melhor MR para os dois adesivos testados e todos os tempos de evaporação avaliados. No entanto, não houve diferenças significativas entre os tempos e modos de evaporação na RT. Os resultados deste estudo indicam que a evaporação a uma temperatura de (40±1) °C poderia melhorar o módulo de elasticidade de ambos os adesivos testados, independentemente do tempo de evaporação.


Subject(s)
Humans , Solvents/pharmacology , Tensile Strength , Adhesives/chemistry , Dentin-Bonding Agents/chemistry , Dental Cements/chemistry , Volatilization , Materials Testing , Desiccation
6.
Int. j. odontostomatol. (Print) ; 14(2): 236-241, June 2020. tab
Article in English | LILACS | ID: biblio-1090680

ABSTRACT

There is no information about the possible impact in denture retention after the use of common denture adhesives (DAs) when poor denture foundations (PDF) are present. Moreover, there is a lack of information about which current formulation provides greater retention and for how long. Twelve models from edentulous patients with different ridge shape and border height were used and complete dentures were manufactured. Four different formulation brands of DAs were tested after 10 minutes and three, six, nine, and 12 hours of DA application using a universal testing machine. The Fittydent® and Fixodent® adhesives had the highest retention at 12 hours. The PDF group increased on average its retention by 400 %. However, the group presented lower retention compared to the good denture foundation group. In conclusion, DAs significantly increased denture retention. The PDF group were the most benefited with the application of DAs. The Fixodent® paste had the highest retention.


No existe información acerca del posible impacto en la retención de dentaduras después del uso de adhesivos dentales comunes (DAs) cuando existen rebordes alveolares deficientes (PDF). Más aun, existe una falta de información acerca de cuál formula actual provee mayor retención y por cuanto tiempo. Doce modelos de pacientes edentulos con diferentes formas y alturas en sus rebordes alveolares fueron usados, y dentaduras completas les fueron realizadas. Cuatro diferentes fórmulas y marcas de DAs fueron evaluadas después de 10 minutos, tres, seis, nueve y 12 horas de que se aplicó el DA usando una maquina universal de pruebas. Los adhesivos Fittydent® y Fixodent® presentaron la retención más alta a las 12 horas. El grupo con PDF incrementó su retención hasta en un 400 %. Sin embargo, el grupo presentó menor retención cuando se comparó con el grupo que posee adecuados procesos alveolares. Los DAs incrementaron significativamente la retención de las dentaduras. El grupo PDF fue el más beneficiado con la aplicación de DAs. La pasta Fixodent® provee la más alta retención.


Subject(s)
Humans , Denture Retention/methods , Dental Cements/chemistry , Alveolar Process , In Vitro Techniques , Adhesives
7.
Int. j. odontostomatol. (Print) ; 14(1): 55-59, mar. 2020. tab, graf
Article in English | LILACS | ID: biblio-1056501

ABSTRACT

ABSTRACT: The aim of this study was to analyze the bond strength of total-etch and self-etch adhesive systems to dentin of primary and permanent teeth. Methods: Thirty sound naturally exfoliated primary molars deciduous teeth (DT) and thirty sound permanent bicuspids permanent teeth (PT) were randomly divided into six groups (n=10 per group) according to two commercial adhesive systems: Adper Single Bond 2; 3M ESPE (Total-etch) and Adper Easy Bond; 3M ESPE (selfetch and total-etch). Specimens submitted to cyclic loading in a universal Instron testing machine. Bond strength values (MPa) were analyzed by ANOVA test and Duncan post hoc test (a=0.05). Results: Mean values were higher in PT compared to DT. In deciduous teeth, no significantly differences observed. Total etch AdperTM Single Bond 2 showed significantly higher bond strength than self-etch AdperTM with additional acid etching in PT (p=0.031). Conclusion: Our findings suggest that the highest bond strength was found in dentin tissue of PT with total etch AdperTM employing the adhesive the Single Bond 2 of one step self-etch.


RESUMEN: El objetivo de este estudio fue analizar la fuerza de unión de los sistemas adhesivos de grabado total y autograbado a la dentina de los dientes primarios y permanentes. Métodos: treinta sonidos exfoliaron naturalmente los molares primarios dientes caducifolios (DT) y treinta sonidos. Los dientes permanentes de los premolares permanentes (PT) se dividieron aleatoriamente en seis grupos (n = 10 por grupo) de acuerdo con dos sistemas adhesivos comerciales: Adper Single Bond 2; 3M ESPE (Grabado total) y Adper Easy Bond; 3M ESPE (autograbado y grabado total). Muestras sometidas a carga cíclica en una máquina universal de pruebas Instron. Los valores de resistencia de la unión (MPa) se analizaron mediante la prueba ANOVA y la prueba post hoc de Duncan (a = 0.05). Resultados: Los valores medios fueron mayores en PT en comparación con DT. En dientes deciduos, no se observaron diferencias significativas. Total etch AdperTM Single Bond 2 mostró una fuerza de unión significativamente mayor que la autograbado AdperTM con grabado ácido adicional en PT (p = 0.031). Conclusión: Nuestros hallazgos sugieren que la mayor fuerza de unión se encontró en el tejido de dentina de PT con grabado total AdperTM empleando el adhesivo Single Bond 2 de autograbado de un solo paso.


Subject(s)
Humans , Dental Bonding , Dentin-Bonding Agents , Dental Cements/classification , Dental Cements/chemistry , Tooth, Deciduous , In Vitro Techniques , Adhesives , Dentition, Permanent , Shear Strength , Molar
8.
Braz. oral res. (Online) ; 34: e001, 2020. tab, graf
Article in English | LILACS | ID: biblio-1055529

ABSTRACT

Abstract This study analyzed the effect of prior application of copaiba oil (CO) emulsions as a dentin cleaning substance on microleakage and microtensile adhesive strength. Twenty-five premolars and sixty-four molars were used for microleakage and microtensile assays. For the microleakage assays, specimens with standard class V cavities were divided (n = 5), according to the tested CO emulsions: CO10%X, CO10%Y, and CO10%Z, as well as chlorhexidine 2% (CHX) and distilled water (DW), as positive and negative controls, respectively. Restorations were performed using the Adper Single Bond® and/or Clearfil SE Bond® systems. Cervical, occlusal, distal and mesial sections were assessed for tracer penetration degree at the composite/tooth interface. For the microtensile assay, healthy molars were divided into sixteen groups, in which artificial caries were induced in half of the groups. Dentin surfaces were treated with CO10%X and CO10%Y, CHX and DW. Microtensile bond strength was measured by fixing each sample to the plate of a universal testing machine operated at a speed of 0.5 mm/minute until failure. Dentin treated with CO10%X showed a lower infiltration rate than dentin treated with the other CO emulsions, CHX2% and DW. According to the microtensile assay, both healthy and affected dentin treated with CO10%X and Adper Single Bond® adhesive system presented higher adhesive strength. CO emulsion, used as a dentin biomodifier, interfered positively in microleakage and improved adhesive strength after acid etching in the Adper Single Bond® adhesive system, or before applying the Clearfil SE Bond® self-etching system.


Subject(s)
Humans , Plant Oils/chemistry , Dental Bonding/methods , Dentin-Bonding Agents/chemistry , Dentin/drug effects , Fabaceae/chemistry , Surface Properties , Tensile Strength , Materials Testing , Chlorhexidine/chemistry , Reproducibility of Results , Analysis of Variance , Statistics, Nonparametric , Composite Resins/chemistry , Resin Cements/chemistry , Dental Cements/chemistry , Dental Leakage , Dentin/chemistry , Emulsions/chemistry
9.
J. appl. oral sci ; 28: e20190105, 2020. tab, graf
Article in English | LILACS | ID: biblio-1056578

ABSTRACT

Abstract Calcium aluminate cement (CAC) has been highlighted as a promising alternative for endodontic use aiming at periapical tissue repair. However, its effects on dental pulp cells have been poorly explored. Objective: This study assessed the impact of calcium chloride (CaCl2) and bismuth oxide (Bi2O3) or zinc oxide (ZnO) additives on odontoblast cell response to CAC. Methodology: MDPC-23 cells were exposed for up to 14 d: 1) CAC with 2.8% CaCl2 and 25% ZnO (CACz); 2) CAC with 2.8% CaCl2 and 25% Bi2O3 (CACb); 3) CAC with 10% CaCl2 and 25% Bi2O3 (CACb+); or 4) mineral trioxide aggregate (MTA), placed on inserts. Non-exposed cultures served as control. Cell morphology, cell viability, gene expression of alkaline phosphatase (ALP), bone sialoprotein (BSP), and dentin matrix protein 1 (DMP-1), ALP activity, and extracellular matrix mineralization were evaluated. Data were compared using ANOVA (α=5%). Results: Lower cell density was detected only for MTA and CACb+ compared with Control, with areas showing reduced cell spreading. Cell viability was similar among groups at days one and three (p>0.05). CACb+ and MTA showed the lowest cell viability values at day seven (p>0.05). CACb and CACb+ promoted higher ALP and BSP expression compared with CACz (p<0.05); despite that, all cements supported ALP activity. Matrix mineralization were enhanced in CACb+ and MTA. Conclusion: In conclusion, CAC with Bi2O3, but not with ZnO, supported the expression of odontoblastic phenotype, but only the composition with 10% CaCl2 promoted mineralized matrix formation, rendering it suitable for dentin-pulp complex repair.


Subject(s)
Humans , Mice , Calcium Compounds/pharmacology , Calcium Compounds/chemistry , Aluminum Compounds/pharmacology , Aluminum Compounds/chemistry , Dental Cements/pharmacology , Dental Cements/chemistry , Dental Pulp/cytology , Dental Pulp/drug effects , Oxides/pharmacology , Oxides/chemistry , Time Factors , Zinc Oxide/pharmacology , Zinc Oxide/chemistry , Bismuth/pharmacology , Bismuth/chemistry , Materials Testing , Calcium Chloride/pharmacology , Calcium Chloride/chemistry , Gene Expression/drug effects , Cell Survival/drug effects , Cells, Cultured , Reproducibility of Results , Silicates/pharmacology , Silicates/chemistry , Drug Combinations , Alkaline Phosphatase/analysis , Alkaline Phosphatase/drug effects , Odontoblasts/drug effects
10.
J. appl. oral sci ; 28: e20190499, 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1101251

ABSTRACT

Abstract Enzymatic degradation of the hybrid layer can be accelerated by the activation of dentin metalloproteinases (MMP) during the bonding procedure. MMP inhibitors may be used to contain this process. Objective To evaluate the degree of conversion (DC%), dentin bond strength (µTBS) (immediate and after 1 year of storage in water), and nanoleakage of an experimental (EXP) and a commercial (SB) adhesive system, containing different concentrations of the MMP inhibitor GM1489: 0, 1 µM, 5 µM and 10 µM. Methodology DC% was evaluated by FT-IR spectroscopy. Dentin bond strength was evaluated by µTBS test. Half of beams were submitted to the µTBS test after 24 h and the other half, after storage for 1 year. From each tooth and storage time, 2 beams were reserved for nanoleakage testing. Data were analyzed using ANOVA and Tukey's test to compare means (α=0.05). Results All adhesive systems maintained the µTBS after 1 year of storage. Groups with higher concentrations of inhibitor (5 µM and 10 µM) showed higher µTBS values than groups without inhibitor or with 1 µM. The nanoleakage values of all groups showed no increase after 1 year of storage and values were similar for SB and EXP groups, in both storage periods. The inhibitor did not affect the DC% of the EXP groups, but the SB5 and SB10 groups showed higher DC% values than those of SB0 and SB1. Conclusions The incorporation of GM1489 in the adhesive systems had no detrimental effect on DC%. The concentrations of 5 µM GM1489 for SB and 5 µM or 10 µM for EXP provided higher μTBS than groups without GM1489, in the evaluation after 1 year of storage; whereas the concentration of inhibitor did not affect adhesive systems nanoleakage.


Subject(s)
Humans , Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Dental Cements/chemistry , Dentin/chemistry , Matrix Metalloproteinase Inhibitors/chemistry , Methacrylates/chemistry , Reference Values , Surface Properties , Tensile Strength , Time Factors , Materials Testing , Reproducibility of Results , Analysis of Variance , Dental Bonding/methods , Spectroscopy, Fourier Transform Infrared , Statistics, Nonparametric , Dental Leakage , Dentin/drug effects , Dental Etching/methods
11.
Braz. oral res. (Online) ; 34: e045, 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1132712

ABSTRACT

Abstract This in vitro study aimed to evaluate the effect of a silane-containing universal adhesive used with or without a silane agent on the repair bond strength between aged and new composites. Forty nanohybrid composite resin blocks were stored in distilled water for 14 d and thermo-cycled. Sandpaper ground, etched, and rinsed speciments were randomly assigned into four experimental groups: silane + two-step etch-and-rinse adhesive system, two-step etch-and-rinse adhesive system, silane + silane-containing universal adhesive system, and silane-containing universal adhesive system. Blocks were repaired using the same composite. After 24 h of water storage, the blocks were sectioned and bonded sticks were submitted to microtensile testing. Ten unaged, non-repaired composite blocks were used as a reference group to evaluate the cohesive strength of the composite. Two-way ANOVA and Tukey's tests were used to analyze average µTBS. One-way ANOVA and Dunnet post-hoc tests were used to compare the cohesive strength values and bond strength obtained in the repaired groups (α = 0.05). The µTBS values were higher for the silane-containing universal adhesive compared to the two-step etch-and-rinse adhesive system (p = 0.002). Silane application improved the repair bond strength (p = 0.03). The repair bond strength ranged from 39.3 to 65.8% of the cohesive strength of the reference group. Using universal silane-containing adhesive improved the repair bond strength of composite resin compared to two-step etch-and-rinse adhesive. However, it still required prior application of a silane agent for best direct composite resin repair outcomes.


Subject(s)
Silanes/chemistry , Composite Resins/chemistry , Resin Cements/chemistry , Dental Cements/chemistry , Reference Values , Surface Properties , Tensile Strength , Time Factors , Materials Testing , Reproducibility of Results , Analysis of Variance , Dental Bonding/methods
12.
Braz. oral res. (Online) ; 34: e001, 2020. tab, graf
Article in English | LILACS | ID: biblio-1089393

ABSTRACT

Abstract This study analyzed the effect of prior application of copaiba oil (CO) emulsions as a dentin cleaning substance on microleakage and microtensile adhesive strength. Twenty-five premolars and sixty-four molars were used for microleakage and microtensile assays. For the microleakage assays, specimens with standard class V cavities were divided (n = 5), according to the tested CO emulsions: CO10%X, CO10%Y, and CO10%Z, as well as chlorhexidine 2% (CHX) and distilled water (DW), as positive and negative controls, respectively. Restorations were performed using the Adper Single Bond® and/or Clearfil SE Bond® systems. Cervical, occlusal, distal and mesial sections were assessed for tracer penetration degree at the composite/tooth interface. For the microtensile assay, healthy molars were divided into sixteen groups, in which artificial caries were induced in half of the groups. Dentin surfaces were treated with CO10%X and CO10%Y, CHX and DW. Microtensile bond strength was measured by fixing each sample to the plate of a universal testing machine operated at a speed of 0.5 mm/minute until failure. Dentin treated with CO10%X showed a lower infiltration rate than dentin treated with the other CO emulsions, CHX2% and DW. According to the microtensile assay, both healthy and affected dentin treated with CO10%X and Adper Single Bond® adhesive system presented higher adhesive strength. CO emulsion, used as a dentin biomodifier, interfered positively in microleakage and improved adhesive strength after acid etching in the Adper Single Bond® adhesive system, or before applying the Clearfil SE Bond® self-etching system.


Subject(s)
Humans , Plant Oils/chemistry , Dental Bonding/methods , Dentin-Bonding Agents/chemistry , Dentin/drug effects , Fabaceae/chemistry , Surface Properties , Tensile Strength , Materials Testing , Chlorhexidine/chemistry , Reproducibility of Results , Analysis of Variance , Statistics, Nonparametric , Composite Resins/chemistry , Resin Cements/chemistry , Dental Cements/chemistry , Dental Leakage , Dentin/chemistry , Emulsions/chemistry
13.
Rev. Soc. Odontol. La Plata ; 29(57): 15-19, dic. 2019. ilus
Article in Spanish | LILACS | ID: biblio-1049929

ABSTRACT

Se determinó la solubilidad en agua en ensayos in-vitro de un sellador para uso endodóntico a base de un conglomerado de trióxidos minerales (MTA), marca Endosealer® (Densell SA) de acuerdo a la norma UNE-EN ISO 6876:2012. En el ensayo de solubilidad en agua durante 24 hs se encontró pérdida de masa (3,3 %) y la presencia de sólidos en las aguas de lavado (6,4 %). Esto indica que durante el ensayo ocurre la solubilización de parte del material y la incorporación de agua, lo que no permite establecer un valor real de la solubilidad.(AU)


Solubility of a commercial endodontic sealer (Endosealer® (Densell SA)) was performed according to the UNE-EN ISO 6876:2012. The results show a mass loss of 3.3 % and 6.4 % of solid in the test solution. These indicate that during the solubility test part of the material solubilizes and an actual value of solubility cannot feasible be determined


Subject(s)
Root Canal Filling Materials , Dental Cements/analysis , Dental Cements/chemistry , Solubility , Dental Materials
14.
Int. j. odontostomatol. (Print) ; 13(1): 64-68, mar. 2019. tab
Article in Spanish | LILACS | ID: biblio-990066

ABSTRACT

RESUMEN: El correcto sellado apical es un paso importante durante el tratamiento de conductos, para esto, se utilizan puntas de gutapercha y cemento sellador, de este último existen diversas formulaciones químicas en el mercado, por lo cual es importante tomar en cuenta los efectos que estas pueden tener en el proceso de cicatrización periapical. El propósito de este estudio fue evaluar la biocompatibilidad de cuatro cementos selladores con diferente composición química con osteoblastos humanos. Se prepararon extractos de cementos selladores a con dos concentraciones (10 mg/mL y 40 mg/mL) y dos tiempos de exposición (10 min y 8 h), estos fueron colocados en contacto con osteoblastos humanos para evaluar la proliferación y citotoxicidad a 24, 72 y 96 h con sus respectivos controles y blancos. Se realizó un análisis estadístico con ANOVA de un factor y la prueba de comparaciones múltiple de Bonferroni. Los resultados obtenidos, tanto en el ensayo de citotoxicidad como en el de proliferación, indicaron que el cemento a base de resina no es biocompatible con osteoblastos. El cemento a base de poli-dimetilxilosano fue el único que no mostró citotoxicidad a ningún de tiempo de exposición y concentración examinadas en este estudio.


ABSTRACT: Correct apical sealing is an important step during root canal treatment, hence, gutta-percha points and sealant are used. There are several chemical compositions on the market, so it is important to evaluate the effects of these in the periapical healing process. The aim of this study was to evaluate the biocompatibility of four sealer cements with different chemical composition placed in contact with human osteoblast. Different extracts were prepared at two concentrations (10 mg/mL and 40 mg/mL) and two exposure times (10 min and 8 h) these were placed in contact with human osteoblast to evaluate cytotoxicity and proliferation at 24, 48 and 72 h with their respective controls and blanks. A statistical analysis was performed with ANOVA of one factor and Bonferroni post hoc. Results obtained in cytotoxicity and proliferation assays, indicated that the resinbased cement is not biocompatible with osteoblast. The poly-dimethylxilosanbased cement was the only that did not show cytotoxicity at any time of exposure and concentration examined in this study.


Subject(s)
Humans , Osteoblasts , Materials Testing/methods , Dental Cements/chemistry , In Vitro Techniques , Analysis of Variance
15.
Braz. oral res. (Online) ; 33: e038, 2019. tab, graf
Article in English | LILACS | ID: biblio-1001609

ABSTRACT

Abstract: This study aimed to evaluate the bond strength of a universal adhesive system to enamel surrounding real-life carious cavities. Twenty-eight permanent molars (n = 7) with carious lesions in dentin were subjected to selective carious tissue removal to firm dentin and had their crowns sectioned longitudinally. A universal adhesive system (Single Bond Universal [SBU] used in either etch-and-rinse and self-etch strategies) was compared with an etch-and-rinse Adper Single Bond 2 (ASB) and a self-etch Clearfil SE Bond (CSE) adhesive systems (control systems). Adhesives were applied on the enamel, assumed demineralized, surrounding the cavity margins and on sound enamel (control substrate). Composite cylinders were built (0.72 mm2) and microshear bond strength (µSBS) test was performed after 24 h of water storage. The µSBS values (MPa) were analyzed using two-way ANOVA and Tukey's post hoc tests (α = 0.05). Bond strength values obtained in demineralized enamel surrounding carious cavity margins were significantly lower than that obtained in sound enamel (distant from carious cavity margins) (p = 0.035). The bonding strategy of the SBU did not influenced the bond strength values, which were higher than that obtained with ASB. CSE showed similar µSBS values to ASB and SBU in the self-etch mode. In conclusion, the bond strength to enamel assumed demineralized is lower than to sound enamel. The enamel surrounding carious cavities jeopardize the bonding of universal adhesive system. The bond strength of universal adhesive is similar, regardless to bonding strategy.


Subject(s)
Humans , Dental Bonding/methods , Bisphenol A-Glycidyl Methacrylate/chemistry , Dental Caries/therapy , Dental Cements/chemistry , Dental Enamel/drug effects , Surface Properties , Materials Testing , Microscopy, Electron, Scanning , Random Allocation , Reproducibility of Results , Analysis of Variance , Bisphenol A-Glycidyl Methacrylate/therapeutic use , Statistics, Nonparametric , Resin Cements/therapeutic use , Resin Cements/chemistry , Dental Cements/therapeutic use , Shear Strength , Dentin/drug effects
16.
Braz. oral res. (Online) ; 33: e010, 2019. tab, graf
Article in English | LILACS | ID: biblio-989483

ABSTRACT

Abstract This in situ study aimed to evaluate the antibacterial and anti-demineralization effects of an experimental orthodontic adhesive containing triazine and niobium phosphate bioglass (TAT) around brackets bonded to enamel surfaces. Sixteen volunteers were selected to use intra-oral devices with six metallic brackets bonded to enamel blocks. The experimental orthodontic adhesives were composed by 75% BisGMA and 25% TEGDMA containing 0% TAT and 20% TAT. Transbond XT adhesive (TXT) was used as a control group. Ten volunteers, mean age of 29 years, were included in the study. The six blocks of each volunteer were detached from the appliance after 7 and 14 days to evaluate mineral loss and bacterial growth including total bacteria, total Streptococci, Streptococci mutans, and Lactobacilli. Statistical analysis was performed using GLM model - univariate analysis of variance for microhardness and 2-way ANOVA for bacterial growth (p<0.05). The 20% TAT adhesive caused no difference between distances from bracket and the sound zone at 10-µm deep after 7 and 14 days. After 14 days, higher mineral loss was shown around brackets at 10- to 30-µm deep for TXT and 0% TAT adhesives compared to 20% TAT. S. mutans growth was inhibited by 20% TAT adhesive at 14 days. Adhesive with 20% TAT showed lower S. mutans and total Streptococci growth than 0% TAT and TXT adhesives. The findings of this study show that the adhesive incorporated by triazine and niobium phosphate bioglass had an anti-demineralization effect while inhibiting S. mutans and total Streptococci growth. The use of this product may inhibit mineral loss of enamel, preventing the formation of white spot lesions.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Oxides/pharmacology , Phosphates/pharmacology , Streptococcus/drug effects , Tooth Demineralization/prevention & control , Dental Cements/pharmacology , Lactobacillus/drug effects , Anti-Bacterial Agents/pharmacology , Niobium/pharmacology , Ceramics/pharmacology , Ceramics/chemistry , Double-Blind Method , Dental Cements/chemistry , Anti-Bacterial Agents/chemistry
17.
J. appl. oral sci ; 27: e20180247, 2019. tab, graf
Article in English | LILACS, BBO | ID: biblio-975879

ABSTRACT

Abstract Objective This study aimed to investigate the effects of dodecacalcium hepta-aluminate (C12A7) content on some physicochemical properties and cytocompatibility of tricalcium silicate (C3S) cement using human dental pulp cells (hDPCs). Material and Methods High purity C3S cement was manufactured by a solid phase method. C12A7 was mixed with the cement in proportions of 0, 5, 8, and 10 wt% (C12A7-0, −5, −8, and −10, respectively). Physicochemical properties including initial setting time, compressive strength, and alkalinity were evaluated. Cytocompatibility was assessed with cell viability tests and cell number counts. Statistical analysis was performed by using one-way analysis of variance (ANOVA) and Tukey's test (p<0.05). Results The initial setting time of C3S-based cement was shorter in the presence of C12A7 (p<0.05). After 1 day, C12A7-5 showed significantly higher compressive strength than the other groups (p<0.05). After 7 days, the compressive strength of C12A7-5 was similar to that of C12A7-0, whereas other groups showed strength lower than C12A7-0. The pH values of all tested groups showed no significant differences after 1 day (p>0.05). The C12A7-5 group showed similar cell viability to the C12A7-0 group (p>0.05), while the other experimental groups showed lower values compared to C12A7-0 group (p<0.05). The number of cells grown on the C12A7-5 specimen was higher than that on C12A7-8 and −10 (p<0.05). Conclusions The addition of C12A7 to C3S cement at a proportion of 5% resulted in rapid initial setting time and higher compressive strength with no adverse effects on cytocompatibility.


Subject(s)
Humans , Silicates/chemistry , Calcium Compounds/chemistry , Aluminum Compounds/chemistry , Dental Cements/chemistry , Dental Pulp Cavity/cytology , Particle Size , Reference Values , Time Factors , X-Ray Diffraction , Biocompatible Materials/pharmacology , Biocompatible Materials/chemistry , Materials Testing , Microscopy, Electron, Scanning , Cell Survival/drug effects , Cells, Cultured , Reproducibility of Results , Silicates/pharmacology , Calcium Compounds/pharmacology , Aluminum Compounds/pharmacology , Compressive Strength , Dental Cements/pharmacology , Dental Pulp Cavity/drug effects
18.
Braz. dent. j ; 29(5): 452-458, Sept.-Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-974181

ABSTRACT

Abstract This study evaluated physicochemical properties, cytotoxicity and bioactivity of MTA Angelus (MTA), calcium silicate-based cement (CSC) and CSC with 30% Ytterbium oxide (CSC/Yb2O3). Setting time was evaluated using Gilmore needles. Compressive strength was evaluated in a mechanical machine. Radiopacity was evaluated using radiographs of materials and an aluminum scale. Solubility was evaluated after immersion in water. Cell viability was evaluated by means of MTT assay and neutral red staining, and the mineralization activity by using alkaline phosphatase activity and Alizarin Red staining. The data were submitted to ANOVA, Tukey and Bonferroni tests (5% significance). The bioactive potential was evaluated by scanning electron microscopy. The materials presented similar setting time. MTA showed the lowest compressive strength. MTA and CSC/Yb2O3 presented similar radiopacity. CSC/Yb2O3 showed low solubility. Saos-2 cell viability tests showed no cytotoxic effect, except to 1:1 dilution in NR assay which had lower cell viability when compared to the control. ALP at 1 and 7 days was similar to the control. MTA and CSC had greater ALP activity at 3 days when compared to control. All the materials present higher mineralized nodules when compared with the control. SEM analysis showed structures suggesting the presence of calcium phosphate on the surface of materials demonstrating bioactivity. Ytterbium oxide proved to be a properly radiopacifying agent for calcium silicate-based cement since it did not affected the physicochemical and biological properties besides preserving the bioactive potential of this material.


Resumo Este estudo avaliou as propriedades físico-químicas, citotoxicidade e bioatividade do MTA Angelus (MTA), cimento à base de silicato de cálcio (CSC) e CSC com 30% de óxido de itérbio (CSC/Yb2O3). O tempo de presa foi avaliado usando agulhas Gilmore. A resistência à compressão foi avaliada em uma máquina mecânica. A radiopacidade foi avaliada utilizando radiografias dos materiais e uma escala de alumínio. A solubilidade foi avaliada após imersão em água. A viabilidade celular foi avaliada por meio do ensaio MTT e coloração de vermelho neutro (NR), e a atividade de mineralização por meio da atividade da fosfatase alcalina e a coloração com Vermelho de Alizarina. Os dados foram submetidos aos testes ANOVA, Tukey e Bonferroni (5% de significância). O potencial bioativo foi avaliado por microscopia eletrônica de varredura. Os materiais apresentaram tempo de presa semelhante. O MTA mostrou menor resistência à compressão. MTA e CSC/Yb2O3 apresentaram radiopacidade semelhante. CSC/Yb2O3 apresentou menores valores de solubilidade. A viabilidade celular realizada pelos ensaios de MTT e NR não revelaram efeitos ctotóxicos em todas as diluições, exceto na diluição 1:1 no NR, o qual mostrou baixa viabilidade celular (p<0.05) em todos materiais testados quando comparado ao controle. A atividade de ALP em 1 e 7 dias foi similar ao controle (p>0.05). MTA e CSC tiveram significante aumento na atividade de ALP aos 3 dias quando comarados ao controle (p>0.05). Todos os materiais apresentaram grande produção de nódulos mineralizados quando comparados ao controle (P<0.05). A análise da SEM mostrou estruturas que sugerem a presença de depósitos de fosfato de cálcio na superfície dos materiais demonstrando bioatividade. O Yb2O3 mostrou ser um agente radiopacificador adequado em cimentos à base de silicato de cálcio uma vez que não afetou as propriedades físico-químicas e biológicas e ainda preservou o potencial bioativo desse material.


Subject(s)
Oxides/chemistry , Ytterbium/chemistry , Bismuth/chemistry , Silicates/chemistry , Calcium Compounds/chemistry , Dental Cements/chemistry , Solubility , Staining and Labeling , Materials Testing , Microscopy, Electron, Scanning , Cell Survival , Aluminum Compounds/chemistry , Compressive Strength , Chemical Phenomena
19.
J. oral res. (Impresa) ; 7(5): 173-177, jun. 5, 2018. tab
Article in English | LILACS | ID: biblio-1120837

ABSTRACT

Objective: to compare the adhesive strength in dentin of three universal adhesive systems in vitro by means of the shear test. materials and methods: seventy-five bovine teeth were selected and cut. dentin was exposed from the buccal surface of the crowns with 220 grit sandpaper, and samples were then inserted in transparent acrylic bases (15x10mm). the samples were randomly divided in 3 groups (n=25): G1-universal adhesive system Scotchbond Universal (3M ESPE-USA); G2- Universal adhesive system Peak Universal Bond (Ultradent); G3-Universal adhesive system Tetric N-Bond (Ivoclar Vivadent). the adhesive procedures were carried out according to the instructions of each manufacturer and the restorative procedures were carried out with micro-cylinders (made of Tygon type tubing 0.79x1.5mm) of the composite resin Filtek Z350XT-A2 (3M ESPE-USA). the samples were incubated at 37ºC (+/-5ºC) for 24 hours. adhesive strength was evaluated in a universal test machine by means of the shear test (0.5mm/min, 500N) and the resulting fracture type was evaluated with a Dinolite digital microscope (x200). the results were analyzed by descriptive statistics (Mean±SD), and inferential statistics by a one-way ANOVA. results: no statistically significant differences were found between the universal adhesive systems evaluated G1 (14.91±4.76), G2 (16.90±4.11) and G3 (17.34±4.04)/(p=0.114). conclusions: the shear test resulted in similar values of immediate adhesive strength of the three universal adhesive systems used.


Subject(s)
Animals , Cattle , Dentin-Bonding Agents/chemistry , Dental Cements/chemistry , In Vitro Techniques , Resin Cements/chemistry , Dental Cements/adverse effects
20.
Braz. dent. j ; 29(2): 189-194, Mar.-Apr. 2018. tab, graf
Article in English | LILACS | ID: biblio-951539

ABSTRACT

Abstract This study investigated the effect of blood-contamination on the push-out bond strength of BiodentineTM (BD) and MTA Angelus® (MTA-A) to root dentin over time. Twenty-five teeth were sectioned horizontally to obtain 120 root slices. The lumens were filled with MTA-A or BD: 60 for each cement (30 uncontaminated and 30 blood contaminated). Push out bond strength to dentin was assessed at 24 h (n=10), 7 days (n=10) and 28 days (n=10). Failure modes were classified as: cohesive, adhesive or mixed failure. Two-way ANOVA was used to investigate the interaction between blood contamination vs. hydration period. Mann Whitney test compared different materials in each period, and it also compared the contaminated versus uncontaminated material for each period. Friedman, followed by Dunn`s test, compared periods of hydration for each material, regardless of blood contamination. Failure modes were reported descriptively. The interaction hydration period vs. blood contamination was highly significant for MTA-A (P=0.001) and it was not significant for BD (P=0.474). There were no differences between bond strength of uncontaminated and contaminated BD in any of the periods. Bond strength of uncontaminated MTA-A increased at each time of hydration; but it remained stable over time for blood-contaminated samples. BD had higher bond strength than MTA-A in all periods of hydration. Cohesive failure predominated. Only for MTA-A, the over time bond strength to dentin was affected by blood contamination.


Resumo Este estudo investigou o efeito da contaminação sanguínea na resistência de união do BiodentineTM (BD) e do MTA Angelus® (MTA-A) à dentina, em diferentes períodos. Vinte e cinco dentes foram seccionados para obter 120 fatias de dentina. Os lúmens das fatias foram preenchidos com MTA-A ou BD: 60 para cada cimento (30 não-contaminados e 30 contaminados com sangue). A resistência de união à dentina foi medida por teste push-out em 24 horas (n=10), 7 dias (n=10) e 28 dias (n=10). Os tipos de falha foram classificados como: falha coesiva, adesiva ou mista. Two-way ANOVA foi usado para investigar a interação entre contaminação sanguínea vs. período de hidratação. O teste de Mann Whitney comparou os diferentes materiais em cada período, e comparou as amostras contaminadas e não contaminadas de cada material em cada tempo. O teste de Friedman, seguido pelo teste de Dunn, comparou os períodos de hidratação de cada material, independentemente da contaminação. A análise estatística mostrou a interação entre contaminação sanguínea vs. período de hidratação. Os tipos de falha foram reportados de maneira descritiva. A interação entre contaminação sanguínea vs. período de hidratação foi altamente significativa para o MTA-A (P=0,001), e não foi significativa para o BD (P=0,474). Não houve diferenças entre a resistência de união entre o BD contaminado e não-contaminado independente do período. A resistência de união do MTA-A não-contaminado aumentou a cada tempo de hidratação; mas, permaneceu estável ao longo do tempo para as amostras contaminadas com sangue. BD obteve maior resistência de união que o MTA-A em todos os períodos de hidratação. Falhas coesivas predominaram. A contaminação ao longo do tempo influenciou a resistência de união no grupo MTA-A.


Subject(s)
Humans , Blood , Materials Testing , Dentin-Bonding Agents/chemistry , Calcium Compounds/chemistry , Aluminum Compounds/chemistry , Dental Cements/chemistry , Oxides/chemistry , Silicates/chemistry , Dental Stress Analysis , Drug Combinations
SELECTION OF CITATIONS
SEARCH DETAIL